The study searched MEDLINE, EMBASE databases, and the Cochrane library through June 2017. Positive reference test was defined as villous atrophy along with positive celiac-specific serology and/or clinical improvement after gluten-free diet. Normal duodenal biopsy was defined as negative reference test. Bivariate random-effect model was used to present the summary estimates of sensitivities and specificities along with 95% confidence regions. The study assessed methodologic quality using the quality assessment of diagnostic accuracy studies-2 tool. The findings highlighted that the pooled sensitivity and specificity of POCTs in diagnosing CD are high. POCTs may be used to screen for CD, especially in areas with limited access to laboratory-based testing. Further research assessing the diagnostic accuracy of individual POCTs and comparing it with other available POCTs is needed.